![Milnor 6458 Installation Manual Download Page 65](http://html1.mh-extra.com/html/milnor/6458/6458_installation-manual_1797124065.webp)
Pellerin Milnor Corporation
Gas, Steam, and Air Intake - Older Dryer Models (cont'd.)
Model number prefix
5040_
50040_
58040_
58058_
58080_
72072_
with tower
72072_ no
tower
@ 13.5"
(343)
@ 13.5"
(343)
@ 13.5"
(343)
@ 18"
(457)
@ 18"
(457)
Steam inlet (steam models)
Maximum lb/hr (kg/hr)
600 (272)
600 (272)
950 (431)
1300 (590)
n.a.
n.a.
Average lb/hr (kg/hr)
127 (280)
173 (382)
561 (254)
765 (347)
n.a.
n.a.
Maximum boiler horse-
power (kw)
17.4 (7.9)
17.4 (7.9)
27.5 (12.5)
37.7 (17.1)
n.a.
n.a.
Average boiler horse-
power (kw)
8.1 (3.7)
11.1 (5.0)
16.3 (7.4)
22.2 (10.1)
n.a.
n.a.
Thermal oil inlet (thermal oil models) - Consult Milnor
®
factory
Main air intake
Maximum scfm (cu m/
min)
3,600 (102) 3,600 (102) 5,000 (142) 6,800 (193)
10,000
(283)
14,000
(396)
Maximum allowable
back pressure
0.5" (water column)
Combustion (non-ducted, ambient) air intake (natural gas and propane models)
Maximum scfm (cu m/
min) to blower
250 (7)
250 (7)
400 (11)
500 (14)
715 (20)
715 (20)
Maximum scfm (cu m/
min) to fire box
400 (11)
n.a.
n.a.
n.a.
900 (25)
900 (25)
1.3.
Other Mechanical Requirements
BNDUUI01.C08 0000243305 A.7 A.4 1/2/20 1:40 PM Released
Main air intake and exhaust ducting
Per document BNDGUI01 “Air and Ductwork Require-
ments for Milnor
®
Pass-through Dryers.”
Sprinkler water inlet
Minimum 35 PSI (2.4 ATU). Must reliably provide 60 USg (227 liters)
per minute for fire safety.
Compressed air inlet
Clean and dry 85 PSI (5.8 ATU) to 110 PSI (7.5 ATU)
Compressed air inlet for optional internal lint filter
85 PSI (5.8 ATU) to 110 PSI (7.5 ATU).
Air usage estimate: 110 scf (3.1 cubic meter) in 15 seconds when activated.
Customer-supplied connector between the gas inlet and the gas supply piping
a listed con-
nector in compliance with ANSI Z21.24 CSA 6.10 “Standard for Connectors for Gas
Appliances”
Customer-supplied tap (gas/propane models)
1/2" NPT plugged tap, accessible for test gauge
connection. Install immediately upstream of the gas supply connections to the dryer.
Gas line vent (gas/propane models)
1/4" stainless steel. Must be vented from the regulator
vent to the exterior of the building.
Steam condensate outlet (steam models)
Per plumbing code. Return condensate to boiler
through a steam trap of the correct size. Two steam traps are available from Milnor
®
: One for
85 - 180 PSI (6 - 12 ATU) and one for 160 - 225 PSI (11 - 15 ATU).
Vacuum breaker (steam models)
Vent the tube to the sewer.
Utility Requirements For Gas, Steam and Thermal Oil Dryers
61
Summary of Contents for 6458
Page 2: ......
Page 8: ......
Page 9: ...Safety 1 5 ...
Page 32: ......
Page 33: ...Installation 2 29 ...
Page 75: ...Installation Drawings 3 71 ...
Page 76: ......
Page 77: ...73 ...
Page 78: ...74 ...
Page 79: ...75 ...
Page 80: ......
Page 81: ...77 ...
Page 82: ...78 ...
Page 83: ...79 ...
Page 84: ...80 ...
Page 85: ...81 ...
Page 86: ......
Page 87: ...83 ...
Page 88: ...84 ...
Page 89: ...85 ...
Page 90: ...86 ...
Page 91: ...87 ...
Page 92: ...88 ...
Page 93: ...89 ...