Figure 3. Example Duct Layout for Model 6464TG1L Dryer
Isometric View of Duct Layout
Legend
CL. . .
Center line.
ED. . .
Exhaust duct. This example uses 26 inch (660 mm) diameter round duct.
FP. . .
Fire protection per construction codes.
GT. . .
Gradual transitions. Treat as straight duct of the same size as their larger end.
ID. . .
Inlet duct. This example uses 24 inch (610 mm) high by 23 inch (584 mm) wide rectangular duct.
NS. . .
No screen on inlet duct fresh air intake.
SE. . .
Smooth elbows (six or more segments). This example uses large radius elbows.