6-8. Remote Voltage Sense Connection
Ref. 804 041-A / 243 336-A
!
Turn off power source and
disconnect input power.
Remove wrapper (see Section 7-4).
Remote voltage sense is an arc
voltage output signal for automatic
torch height adjustment.
1
Snap-in Blank
2
Secondary Interconnect
Board PC4
3
Receptacle RC48
Remove snap-in blank from rear
panel.
Route plug end of cable through
opening in rear panel.
Route plug end of cable over to
PC4.
Allowing adequate slack inside the
machine, secure cable and strain
relief by snapping strain relief into
opening in rear panel.
Connect plug to RC48 on PC4.
Install wrapper on unit.
Cut off crimped terminals on lead
ends, and connect lead 1 to +volts
DC (work) and lead 2 to
−
volts DC
(electrode) on customer-supplied
voltage sense device.
3
2
1
Tools Needed:
Torx 25
6-9. Shield Sense Tab
.
Shield sense tab is located in
the consumable storage box
on left side of unit wrapper.
Shield sense tab is included
only with units originally sold
with machine torches.
Shield sense tab provides feedback to a
compatible torch height controller before
starting the cutting process. Place the shield
sense tab between the cup and shield.