A complete Parts List is available at www.MillerWelds.com
OM-242 880 Page 11
SECTION 4
−
INSTALLATION
4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the bottom. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Specifications
Power Supply
Input
Rated AC Phase and line frequency (Hz)
1
−
3
−
Phase
50 / 60 Hz
−−
Rated Input Voltage (U1) and rated Input Current (I1)
and I1 eff at rated output. I1 eff used to determine
power cord rating
Volts AC RMS
−
(U1)
Amps RMS
−
(I1)
I1 eff
208 VAC 1
−
Phase
47.4
30
230 VAC 1
−
Phase
42.2
26.7
208 VAC 3
−
Phase
27.5
19.4
230 VAC 3
−
Phase
25
17.7
380 VAC 3
−
Phase
15
11.6
460 VAC 3
−
Phase
12.4
9.6
575 VAC 3
−
Phase
9.8
7.6
Power Factor/kVA/kW at Rated Output
Volts AC RMS
−
(U1)
Power Factor
kVA/kW
208 VAC 1
−
Phase
0.98
9.9 / 9.7
230 VAC 1
−
Phase
0.98
9.7 / 9.6
208 VAC 3
−
Phase
0.95
9.9 / 9.5
230 VAC 3
−
Phase
0.95
9.9 / 9.5
380 VAC 3
−
Phase
0.95
9.9 / 9.4
460 VAC 3
−
Phase
0.95
9.9 / 9.4
575 VAC 3
−
Phase
0.95
9.8 / 9.3
Peak kW at Arc Stretch
15.5 kW
−−
−−
Output
Rated Open Circuit Voltage (U0) Type
400 Volts DC/Electrode Negative
−−
−−
Output Characteristic
Constant Current
−−
−−
Rated Output Current (I2)
60 A
−−
−−
Rated Output Voltage (U2)
140 Volts DC
−−
−−
Output Current Range
20
−
60 A
−−
−−
Duty Cycle at 104
°
F (40
5
C) and Rated Conditions
(U1, I1, U2, I2) based on a 10 minute period
Duty Cycle %
Amps DC
−
(I2)
Volts AC RMS
−
(U1)
40
60 A
208
−
230 VAC
1
−
Phase
50
60 A
208
−
230 VAC
3
−
Phase
60
60 A
380
−
575 VAC
3
−
Phase
100
50 A
208
−
230 VAC
1
−
Phase
100
50 A
208
−
575 VAC
3
−
Phase
Summary of Contents for CE-60T
Page 51: ...OM 242 880 Page 47 Notes ...
Page 52: ...OM 242 880 Page 48 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram ...
Page 53: ...OM 242 880 Page 49 243 018 C ...
Page 57: ...Notes ...
Page 58: ...Notes ...