OM-4428 Page 40
8-3. Optional Generator Power Receptacles (Standard Models)
2
1
120 V 20 A AC GFCI
Receptacle GFCI1
2
240 V 16 A AC European
Receptacle RC1
3
240 V 15 A AC Australian
Receptacle RC1
4
240 V 15 A AC South African
Receptacle RC1
Receptacles supply 60 Hz single-
phase power at weld/power speed.
If a ground fault is detected, the
GFCI Reset button pops out and
the receptacle does not work.
Check for faulty tools plugged in
receptacle. Press button to reset
GFCI1.
At least once a month, run en-
gine at weld/power speed and
press test button to verify GFCI
is working properly.
5
Supplementary Protector CB2
6
Supplementary Protector CB3
CB2 protects GFCI1 from overload.
If CB2 opens, GFCI1 does not
work. Press button to reset.
CB3 protects RC1 from overload. If
CB3 opens, RC1 does not work.
Press button to reset.
If a supplementary protector
continues to open, contact
Factory Authorized Service
Agent.
Generator power is not af-
fected by weld output.
Maximum output is 2.4 kVA/kW
from GFCI1 and 4 kVA/kW from
RC1. Maximum output from all re-
ceptacles is 4 kVA/kW.
EXAMPLE: If 13 A is drawn from
RC1, only 7 A is available at GFCI1:
(240 V x 13 A) + (120 V x 7 A) =
4.0 kVA/kW
1
5
191 624
3
1
4
1
6
5
6
5
6
European Receptacle
Australian Receptacle
South African Receptacle
Summary of Contents for 600 X
Page 17: ...OM 4428 Page 13 3 2 Manufacturer s Rating Labels CC Models CC CV Models...
Page 67: ...OM 4428 Page 63 215 221 E...
Page 69: ...OM 4428 Page 65 235 275 A...
Page 71: ...OM 4428 Page 67 215 806 E...
Page 73: ...OM 4428 Page 69 235 276 A...
Page 75: ...OM 4428 Page 71 215 807 D...
Page 77: ...OM 4428 Page 73 215 808 D...
Page 106: ......