OM-4428 Page 77
SECTION 14
−
GENERATOR POWER GUIDELINES
The views in this section are intended to be representative of all engine-driven welding generators. Your unit may differ from those shown.
14-1. Selecting Equipment
gen_pwr 2007
−
04
−
Ref. ST-159 730 / ST-800 577
1
Generator Power Receptacles
−
Neutral Bonded To Frame
2
3-Prong Plug From Case
Grounded Equipment
3
2-Prong Plug From Double
Insulated Equipment
Be sure equipment has double
insulated symbol and/or word-
ing on it.
!
Do not use 2-prong plug un-
less equipment is double in-
sulated.
OR
2
3
1
!
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
!
Also see AWS Safety &
Health Fact Sheet No. 29,
Grounding of Portable And
Vehicle Mounted Welding
Generators.
1
Equipment Grounding
Terminal (On Front Panel)
2
Grounding Cable (Not
Supplied)
3
Metal Vehicle Frame
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger
insulated copper wire.
Electrically bond generator
frame to vehicle frame by met-
al-to-metal contact.
!
Bed liners, shipping skids,
and some running gear insu-
late the welding generator
from the vehicle frame. Al-
ways connect a ground wire
from the generator equip-
ment grounding terminal to
bare metal on the vehicle
frame as shown.
!
If unit does not have GFCI re-
ceptacles, use GFCI-pro-
tected extension cord.
14-2. Grounding Generator To Truck Or Trailer Frame
S-0854
GND/PE
3
1
2
Summary of Contents for 600 X
Page 17: ...OM 4428 Page 13 3 2 Manufacturer s Rating Labels CC Models CC CV Models...
Page 67: ...OM 4428 Page 63 215 221 E...
Page 69: ...OM 4428 Page 65 235 275 A...
Page 71: ...OM 4428 Page 67 215 806 E...
Page 73: ...OM 4428 Page 69 235 276 A...
Page 75: ...OM 4428 Page 71 215 807 D...
Page 77: ...OM 4428 Page 73 215 808 D...
Page 106: ......