OM-4428 Page 32
6-3. Remote Amperage Control On CC Models (Optional)
1
Remote Amperage Adjust
Receptacle RC13
Connect optional remote control to
RC13 (see Section 5-11).
Example: Combination Remote Amperage Control (Stick)
Adjust Optional Remote Control
Set Switches
Set Range
Set Control
Ref. 154 862-A / Ref. 215 663 / 803 602
In Example:
Range = 115 to 330 A DC
Percentage Of Range = 50%
Max = About 240 A DC (50% of 150 to 330)
Max (240 A DC)
Min (84 A DC)
1
6-4. Weld Control/Arc Condition Information Label
Set weld controls as shown to
achieve softer or stiffer arc condi-
tions for different applications.
212 944-A