Bootstrap
MIKROTRON GmbH
6
‐
11
ControlPacketSizeMax
This register provides the maximum control packet size the host can
read from the device or write to the device. The size is defined in
Bytes and will be a multiple of 4 Bytes. The defined size is that of the
entire packet, not only the payload.
StreamPacketSizeMax
This register holds the maximum stream packet size the host can
accept. The size is defined in Bytes and will be a multiple of 4 Bytes.
The defined size is that of the entire packet, not only the payload.
Access
read
Type
unsigned integer
In
—
Out
control packet size in multiples of 4 Bytes
Remark
the control packet size is at least 128 Bytes
Access
read / write
Type
unsigned integer
In
stream packet data size in multiples of 4 Bytes
Out
stream packet data size in multiples of 4 Bytes
Remark
The device can use any packet size it wants to up to this size.
A connection reset sets the value to 0x00000000.
Summary of Contents for EoSens CAMMC1186
Page 1: ...EoSens 1 1CXP Camera Reference Guide V1 2...
Page 74: ...CHAPTER 11 Custom Features The chapter informs about the connected device on page 11 3...
Page 87: ...APPENDIX A Technical Data...
Page 89: ...APPENDIX B Spectral Response...
Page 91: ...APPENDIX C Bayer Pattern...
Page 94: ...APPENDIX D Camera Dimensions...
Page 95: ...Camera Dimensions MIKROTRON GmbH D 2 MC1186 and 1187 Rear View...