Acquisition Control
MIKROTRON GmbH
5
‐
8
ExposureTime
If the exposure mode is set to Timed or no hardware trigger is
defined, this feature allows to define the duration of exposure [µs].
ExposureTimeMax
Remark: This feature will
soon expire. Use Exposure
‐
Time to get the highest pos
‐
sible exposure time.
This feature returns the highest possible exposure time for the cur
‐
rent camera settings in [µs].
AcquisitionFrameRate
Tip:
If TriggerMode = ON,
AcquisitionFrameRate will
be disabled.
This feature defines the acquisition rate in
[
Hz
]
when TriggerMode
is OFF
.
Access
read / write
Type
unsigned integer
In
1 … highest possible exposure time
Out
current exposure time
Remark
incremented by 1
Access
read
Type
unsigned integer
In
—
Out
max. exposure time
Remark
The exposure time depends on the current frame rate settings.
Access
read / write
Type
unsigned integer
In
>10... highest possible frame rate
Out
AcquisitionFrameRate
Remark
incremented by 1; min. 10