Acquisition Control
MIKROTRON GmbH
5
‐
7
TriggerDebouncer
Tip:
The best way to find the
appropriate value for the
debounce period is to mea
‐
sured it with an oscillo
‐
scope.
In TriggerDebouncer the debounce period is defined. This period
starts with the occurrence of a trigger edge. Within the debounce
period, a new trigger signal will be ignored. Debouncing might e.g. be
necessary if the trigger signal jitters.
ExposureMode
This feature sets the operation mode of the shutter. It defines how
long a picture will be exposed if TriggerMode is activated.
Access
read / write
Type
integer
In
min.
max.
0
μ
s
430
μ
s
Out
the set debounce period
Remark
The default value amounts to 1
μ
s.
Access
read / write
Type
enumeration
In
Timed
Trigger
Width
exposure time is defined in the feature
ExposureTime;
width of the current trigger signal pulse is usedto
control the exposure time; if TriggerActivation
is
set to RisingEdge, it will be the time the trigger
stays high; if TriggerActivation
is set to Falling
Edge it will last as long as the trigger stays low.
Out
set exposure mode
Remark
ExposureMode is enabled in trigger mode only.
If you choose AnyEdge in TriggerActivator, Timed has to be set.
Timed also has to be set if the TriggerSelector is set to
FrameBurstStart.
Summary of Contents for EoSens CAMMC1186
Page 1: ...EoSens 1 1CXP Camera Reference Guide V1 2...
Page 74: ...CHAPTER 11 Custom Features The chapter informs about the connected device on page 11 3...
Page 87: ...APPENDIX A Technical Data...
Page 89: ...APPENDIX B Spectral Response...
Page 91: ...APPENDIX C Bayer Pattern...
Page 94: ...APPENDIX D Camera Dimensions...
Page 95: ...Camera Dimensions MIKROTRON GmbH D 2 MC1186 and 1187 Rear View...