![Mikrotron EoSens 12CXP+ Reference Manual Download Page 56](http://html1.mh-extra.com/html/mikrotron/eosens-12cxp/eosens-12cxp_reference-manual_1794708056.webp)
Bootstrap CoaXPress
MIKROTRON GmbH
7 - 14
TestErrorCount
This register provides the current connection error count for the con-
nection referred to by the register TestErrorCountSelector.
TestPacketCountTx
This register provides the current transmitted connection test packet
count for the connection referred to by the register
TestErrorCountSe
‐
lector
.
Access
read / write
Type
unsigned integer
In
0x00000000
Out
error count
Remark
Writing 0x00000000 to this register resets the error count for
the connector referred to by the register TestErrorCountSelector
to zero.
A connection reset sets all connection test counters to zero. The
error count is the number of incorrect words that have been
received in test packets.
Access
read / write
Type
integer
In
0x0000000000000000
Out
packet count
Remark
Writing 0x0000000000000000 into this register will reset to zero
the transmitted connection packet count for the connection
referred to by the register TestErrorCountSelector. A connection
reset sets all connection test counters to zero.