ConnectionConfig
This register holds a valid combination of the device link speed and
the number of active down connections. Writing into this register sets
the connection speeds on the specified connections.
ConnectionConfigDefault
This register provides the value of the ConnectionConfig register that
allows the Device to operate in default mode. This feature is used to
start the camera with the default configuration that is stored in the
custom profiles.
Access
read / write
Type
enumeration
In
connection configuration example (read the electronically read-
able manual for further information):
CONNECTION1SPEED3125
one connection of 3.125 Gbps per
connection
CONNECTION2SPEED3125
two connections of 3.125 Gbps per
connection
CONNECTION4SPEED3125
four connections of 3.125 Gbps per
connection (default)
CONNECTION1SPEED5000
one connection of 5.000 Gbps per
connection
CONNECTION2SPEED5000
two connections of 5.000 Gbps per
connection
CONNECTION4SPEED5000
four connections of 5.000 Gbps per
connection
CONNECTION1SPEED6250
one connection of 6.250 Gbps per
connection
CONNECTION2SPEED6250
two connections of 6.250 Gbps per
connection
CONNECTION4SPEED6250
four connections of 6.250 Gbps per
connection
Out
connection configuration
Access
read
Type
unsigned integer
In
—
Out
0x00000000
Remark
Summary of Contents for EoSens 12CXP+
Page 1: ...EoSens 12CXP Camera Reference Guide V1 2...
Page 77: ...APPENDIX A Technical Data...
Page 79: ...APPENDIX B Spectral Response...
Page 82: ...APPENDIX C Bayer Pattern...
Page 85: ...APPENDIX D Camera Dimensions...
Page 86: ...Camera Dimensions MIKROTRON GmbH D 2 Rear View Front View...
Page 87: ...Camera Dimensions MIKROTRON GmbH D 3 Side View...