Bootstrap CoaXPress
MIKROTRON GmbH
7 - 10
DeviceConnectionID
This register provides the ID of the device connection via which this
register is read.
ConnectionReset
Writing 0x00000001 into this register will reset the connection of the device.
MasterHostConnectionID
This register holds the host connection ID of the host connected to
the device master connection.
Access
read
Type
unsigned integer
In
—
Out
connection ID
Remark
A connection ID of zero means that the connection is a master
connection. This is a static register, but with a different value
depending from which connection it is read.
Access
read / write
Type
unsigned integer
In
0x00000001
Out
0x00000000
Remark
A link reset will stop a running image acquisition.
A connection reset command via the master connection (con-
nection 0) will reset a connection and activate its discovery con-
nection configuration within 200 ms. The camera resets the
register to 0x00000000 when it has activated its discovery con-
nection configuration. Writing by the host should be regarded as
“fire and forget” without waiting for acknowledgment.
In general it is not possible to read this register while it has the
value 0x00000001.
Access
read/write
Type
unsigned integer
In
host link ID
Out
host link ID
Remark
The value 0x00000000 is reserved to indicate an unknown Host
ID. All writings to device extension connection will be ignored.
Summary of Contents for EoSens 12CXP+
Page 1: ...EoSens 12CXP Camera Reference Guide V1 2...
Page 77: ...APPENDIX A Technical Data...
Page 79: ...APPENDIX B Spectral Response...
Page 82: ...APPENDIX C Bayer Pattern...
Page 85: ...APPENDIX D Camera Dimensions...
Page 86: ...Camera Dimensions MIKROTRON GmbH D 2 Rear View Front View...
Page 87: ...Camera Dimensions MIKROTRON GmbH D 3 Side View...