GUIDA RAPIDA
OMEGA
3
YARD BASIC
Regolazione del processo di saldatura
Tenere premuta la manopola (11A) per aprire il menù dei parametri secondari.
Selezionare il parametro girando la manopola (10) e regolarlo girando la manopola (11).
Per chiudere il menù premere brevemente (11A).
Premere per breve tempo (12) per attivare la visualizzazione di Fxx (F = function) nomi parametri
on/off.
Parametri MIG/MAG
Corrente di saldatura (A)
Figura 1
Tabella 1
Processo
1,0 mm
1,5 mm
2,0 mm
3,0 mm
Materiale Filo
Gas
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
Fe
0,8
CO
2
2,5
19,0
4,5
19,5
7,0
21,0
11,0
27,0
Fe
1,0
CO
2
2,0
18,0
2,5
19,0
3,0
20,0
4,5
21,0
Fe
1,2
CO
2
1,0
18,0
2,0
20,0
2,5
21,0
3,5
22,0
Fe
0,8
ArCO
2
3,0
16,0
6,0
18,0
7,5
19,5
11,0
20,0
Fe
1,0
ArCO
2
2,0
15,0
3,0
16,0
4,0
17,0
6,0
19,0
Fe
1,2
ArCO
2
1,5
16,5
2,5
17,5
3,5
18,0
4,5
20,5
Fe
1,6
ArCO
2
1,0
17,0
2,0
18,0
2,5
18,5
CrNi
1,0
ArCO
2
3,0
15,0
4,0
16,0
6,0
17,0
8,5
20,0
CrNi
1,2
ArCO
2
2,0
15,0
3,0
16,0
3,5
16,5
6,0
18,0
AI
1,0
Ar
4,0
14,5
6,0
15,0
7,5
16,0
9,0
19,0
AI
1,2
Ar
3,5
13,0
5,0
15,0
8,0
16,0
9,0
17,0
Processo
4,0 mm
6,0 mm
10,0 mm
Materiale Filo
Gas
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
Fe
0,8
CO
2
13,0
29,0
18,0
30,0
24,0
37,0
Fe
1,0
CO
2
6,0
22,5
9,0
24,5
14,0
32,0
Fe
1,2
CO
2
4,5
23,0
7,5
28,5
11,0
36,0
Fe
0,8
ArCO
2
14,0
26,0
18,0
31,0
24,0
33,0
Fe
1,0
ArCO
2
8,0
20,0
11,5
26,5
16,0
30,0
Fe
1,2
ArCO
2
5,5
20,5
8,0
29,0
10,0
32,0
Fe
1,6
ArCO
2
3,0
19,5
4,0
22,0
5,5
29,0
FeFlux
1,2
ArCO
2
6,0
21,0
8,0
25,0
11,0
28,0
CrNi
1,0
ArCO
2
9,0
25,0
10,0
27,0
CrNi
1,2
ArCO
2
8,0
24,0
10,0
24,0
12,0
31,0
AI
1,0
Ar
11,0
22,0
13,0
25,0
15,0
27,0
AI
1,2
Ar
10,0
18,0
13,0
23,0
15,0
26,0
Tabella parametri di saldatura (set value)
Parametri MMA
Quando si sia impostato il programma MMA sono
selezionabili solo i seguenti parametri :
Corto circuito
Corrente di
saldatura (A)
Pr.G / F31
Pre-gas
(0,2 sec.)
S.St / F32
Soft start
(1,0 m/min.)
bb.t / F37
Burn-Back
(5 (0-30))
Po.G / F38
Post-gas
(3,0 sec.)
SP.t / F39
Tempo puntatura/Spot time (0,0 sec.)
A
t
S
t1
m/min
S
S
t2
t
GS.F / F22
(gas flow) 0,5-27 l/min (solo macchine con IGC) (kit opzionale)
A
t
t
HS.A / F11
Hotstart
(25%)
HS.t / F12
Tempo di Hotstart (0,5 sec.)
Arc / F13
Arc force
(25%)
IT 501
1
3783 A