Plumbing
Connection to hot water
supply
To keep electricity consumption costs
down this machine can be connected
to a
(ring) piped hot water supply
. The
maximum temperature must not ex-
ceed 70°C.
It is not economical to run it from an in-
dividual hot water supply if it is not in
continuous use, as the water in the sup-
ply pipes cools down and more energy
would be required to reheat the water.
The machine must not be con-
nected to hot water only, for func-
tional reasons.
For hot water connection the same con-
ditions apply as for cold water connec-
tion.
If the machine is not installed for hot
water connection:
both inlet hoses can be connected
to cold water using an adapter
piece, without the machine being re-
programmed
or
unscrew inlet hose (red stripes)
plug the inlet connection with the
cap supplied.
The machine will have to be repro-
grammed by an authorized service
dealer.
42