Please take note of the installation dia-
gram and instructions supplied. They are
important for the proper connection of
supplies.
Plumbing
The water hook up is by a water valve, which
conforms with local and national regulations.
This work must be carried out by a Miele
authorized service technician.
To ensure the machine is correctly connec-
ted please follow the installation plan and
the installation instructions supplied with the
machine.
The inlet pressure hoses supplied with the
machine must be used for connection to the
water supply.
To ensure the hot water inlet hose (marked
194°F/90°C) lasts for many years, do not
hook the hose up to a hot water connection
supplying water hotter than 158°F/70°C.
This hose should only be replaced with a ge-
nuine Miele spare parts.
A water pressure flow rate of at least 30 psi
(2 bar), maximum 145 psi (10 bar) is requi-
red.
Water taken into the machine must not ex-
ceed a temperature of 158°F/70°C.
Connection to cold water only
See the Installation diagram supplied
Electrical connection
All electrical work must be performed by a
qualified technician in accordance with ap-
plicable codes and standards.
The machine must only be connected to the
voltage and frequency shown on the data
plate.
The machine is supplied as standard for
connection to a 208 V, 60 Hz, 20 A,
single-phase electricity supply.
The electric heater rating is factory preset to
15 kW.
The minimum suds level required for activa-
ting the heating is given in 50 mm column of
water.
The motor has an overload protection
switch.
Connection should be made via a suitable,
approved isolator, with an on-off switch easi-
ly accessible for servicing.
WARNING
THIS APPLIANCE MUST BE
GROUNDED
!
Steam connection
Steam connection must only be undertaken
by an authorized Miele installer.
All removable outer housing parts must
be refitted after the machine has been in-
stalled and the necessary connections
made to on-site supplies.