Electrical connection U.K.
All electrical work should be carried out
by a suitably qualified and competent
person, in strict accordance with
current national and local safety
regulations (BS 7671 in the UK).
Ensure power is not supplied to the
appliance until after installation work
has been carried out.
The appliance is supplied with a mains
cable with moulded plug ready for
connection to a 230-240V mains
supply.
Please ensure the connection data
quoted on the data plate match the
household mains supply.
Connection should be made via a
suitable switched socket which is easily
accessible after installation.
For extra safety it is advisable to protect
the appliance with a suitable residual
current device (RCD). Contact a
qualified electrician for advice.
Do not connect via an extension lead.
Extension leads do not guarantee the
required safety of the appliance (e.g.
danger of overheating).
Non-rewireable plugs BS 1363
The fuse cover must be refitted when
changing the fuse, and if the fuse cover
is lost, the plug must not be used until a
suitable replacement is obtained. The
colour of the correct replacement cover
is that of the coloured insert in the base
of the plug, or the colour that is
embossed in words on the base of the
plug (as applicable to the design of
plug fitted).
Replacement fuses should be ASTA
approved to BS 1362 and have the
correct rating. Replacement fuses and
fuse covers may be purchased from
your local electrical supplier.
WARNING: THIS APPLIANCE
MUST BE EARTHED
Installation and connection
59
Summary of Contents for W 3370
Page 69: ...69 ...
Page 70: ...70 ...
Page 71: ...71 ...
Page 72: ...Alteration rights reserved 2513 W 3370 Edition 111 M Nr 09 655 840 00 M Nr 09 655 840 00 ...