Technical Information
52
T 80xx
Cause:
Heater relay (1K1/1, 2K1/1) defective.
Remedy:
Check the heater relay (1K1/1, 2K1/1).
Cause:
Temperature limiter (F2) defective.
Remedy:
Check temperature limiter F2 for continuity.
Note:
To delete this fault indication, disconnect the dryer from power.
3.9
F3 - Short Circuit in Fill-Ring NTC (1R30)
Symptom:
“Hand Iron” LED flashes.
Program stop.
Cooldown.
Buzzer intermittently for 2 minutes.
Only the “Cold air” program works.
Cause:
Short circuit in fill-ring NTC (1R30). Short circuit: Fill-ring NTC resistance >
320°F (160°C); refer to Table 030-2.
Remedy:
1. Check the wiring harness of the fill-ring NTC for short circuits.
2. For the fill-ring NTC characteristic curve setting, refer to Table 030-2.
Note:
To delete this fault indication, disconnect the dryer from power.
3.10
F4 - Open Circuit in Fill-Ring NTC (1R30)
Symptom:
“Hand Iron” LED flashes.
Program stop.
Cooldown.
Buzzer intermittently for 2 minutes.
Only the “Cold air” program works.
Cause:
Open circuit in fill-ring NTC (1R30). Open circuit: Fill-ring NTC resistance <
-5°F (15°C); refer to Table 030-2.
Remedy:
1. Check the wiring harness of the fill-ring NTC for an open circuit.
2. For the fill-ring NTC characteristic curve setting, refer to Table 030-2.
Note:
To delete this fault indication, disconnect the dryer from power.
Summary of Contents for T 80 Series
Page 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Page 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Page 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Page 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Page 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Page 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Page 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...