T 80xx
1 Technical
Data
Drum design
Honeycomb design
Maximum load
T 80xx, T 80xx C: 13.2 lbs (6 kg)
T 8019 CI: 11 lbs (5 kg)
Drum volume
T 80xx, T 80xx C: 28 gal (105L)
T 8019 CI: 26 gal (100L)
Drum light (H3/6)
E 14 bayonet closure, activation via relay on the
electronic (EPWL). USA: 120V, 15W, 572°F (300°C)
Heater bank
Duct heater bank (R1, R2); 2-filament
Heater output
USA/CAN:
120/208-240 V, 60Hz: 2.6kW (1.44kW +
1.16kW)
MEX:
127/220V, 60Hz: 2.6kW (1.44kW + 1.16kW)
Temperature sensor
Heater bank NTC (2R30), position at heater bank (R1,
R2), drum perforation temperature
Temperature limiter
Temperature limiter (F2, SOD), position at heater bank
(R1, R2) - air entrance to drum, 347°F (175°C) ± 8
degrees
Vented dryer: ¾” (1.9 cm); condenser dryer: ½” (1.3 cm)
Table 030-1:
Technical Data
Temperature Resistance
(k
Ω
)
°F
°C
Heater bank NTC (2R30)
Drying-air NTC (1R30)
32 0
340
38.0
41 5
261
29.7
50 10
203
23.4
59 15
159
18.6
68 20
126
14.9
77 25
100
12.0
86 30
80.2
9.73
95 35
64.8
7.96
104 40
52.7
6.55
113 45
43.1
5.42
122 50
35.5
4.52
131 55
29.4
3.78
140 60
24.5
3.19
149 65
20.5
2.70
158 70
17.3
2.29
167
75
14.6
1.96
176 80
12.5
1.68
185 85
10.6
1.45
194 90
9.13
1.25
199 93
8.34
1.15
203 95
7.86
1.09
212 100
6.80
1.06
230 110
5.14
0.73
248 120
3.95
0.569
Summary of Contents for T 80 Series
Page 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Page 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Page 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Page 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Page 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Page 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Page 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...