Technical Information
24
T 80xx
2.4
Interior Drum Light (H3/6)
Time controlled: 1 second after the door is opened.
Shutoff delay: 5 minutes.
The light is always switched off when the door is closed.
3 Fault
Repair
3.1 Temperature
Limiter
(Thermostat) F2 Has Tripped
Symptom:
The temperature limiter has tripped repeatedly.
Cause:
Clogged door lint filter.
The door lint filter was cleaned with water and not dried afterwards.
A water film covers the door lint filter; the result is that air circulation is
reduced. This causes the drying air temperature to rise at the heater bank,
and then the thermostat switches the heater off.
Remedy:
Clean and dry the door lint filter.
Cause:
Condenser dryers only:
The lint filter in the fill ring is clogged.
The fill-ring lint filter was cleaned with water and not dried afterwards.
A water film covers the fill-ring lint filter; the result is that air circulation is
reduced. This causes the drying-air temperature to rise at the heater bank,
and then the thermostat switches the heater off.
Remedy:
Clean and dry the fill-ring lint filter.
Cause:
Condenser dryers only:
Heat exchanger is clogged.
Remedy:
Clean the heat exchanger.
Cause:
Vented dryers only:
Air duct grids are clogged.
Remedy:
Clean the air duct grids.
Cause:
Air vents/exhaust vents are clogged.
Remedy:
Clean the air vents/exhaust vents.
Cause:
Drum is sluggish.
Remedy:
Summary of Contents for T 80 Series
Page 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Page 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Page 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Page 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Page 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Page 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Page 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...