Technical Information
26
T 80xx
Figure 030-1:
Heater Bank Removal
9. Disconnect the connections from the heater bank NTC and the
temperature limiter (Figure 030-2, Items 2 and 3).
10. Remove the T20 screw securing each temperature limiter bracket (Figure
030-2, Item 3); remove the temperature limiter assemblies from the
heater bank housing.
11. Remove the two T20 screws securing the heater bank to the appliance
rear panel (Figure 030-2, Item 1) and take off the heater bank.
Summary of Contents for T 80 Series
Page 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Page 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Page 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Page 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Page 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Page 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Page 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...