External dosing devices
82
17.4 Examples
Connecting an external detergent dosing device
Hose pump with time-delay relay and fixed output
Connect to “
WASH
” terminal.
Set time-delay relay on the dosing device.
Hose pump with adjustable output
Connect to “
DETERGENT
” terminal.
Programming the transfer strip (
Parallel to the solenoid valve
Set the output (ml/min) amount at the dosing device.
For hose pump with fixed output (e.g. ESP 166, ESP 166C, SP 166Z)
Connect to “
DETERGENT
” terminal.
Programming the transfer strip (
Time-controlled
.
Setting the output on the display (
Set both potentiometers to max.
Set dosing amount on the machine.
Connecting an external rinse aid dosing device
Hose pump with adjustable output
Connect to “
RINSE
” terminal.
Programming the transfer strip (
Parallel to the rinse pump
.
Set the output (ml/min) amount at the dosing device.
For hose pump with fixed output (e.g. ESP 166, ESP 166C, SP 166Z)
Connect to “
RINSE
” terminal.
Programming the transfer strip (
Time-controlled
.
Setting the output (ml/min) on the display (
Set potentiometer to max.
Set dosing amount on the machine.
1
2
3
1
2