![Miele KM 6113 Operating And Installation Instructions Download Page 64](http://html.mh-extra.com/html/miele/km-6113/km-6113_operating-and-installation-instructions_234353064.webp)
Electrical connection
*INSTALLATION*
64
Risk of damage from incorrect
connection.
Unauthorised installation, mainten-
ance and repairs can cause consid-
erable danger for the user.
Miele cannot be held liable for dam-
age or injury caused by unauthorised
installation, maintenance or repair
work, or by an inadequate or faulty
on-site earthing system (e.g. electric
shock).
This hob must be connected to the
electrical supply by a qualified elec-
trician.
The electrician must be familiar with
and comply with the national regula-
tions and any additional regulations
of the local electricity provider (e.g.
BS 7671 in the UK).
After installation, ensure that all elec-
trical components are shielded and
cannot be accessed by users.
Connection
AC 230 V, 50 Hz
The connection data is quoted on the
dataplate. It must match the household
supply.
Please see wiring diagram for connec-
tion. (N.B. This appliance is supplied
single phase only in the UK / AUS / NZ).
Residual current device
For extra safety, it is advisable to pro-
tect the appliance with a suitable resid-
ual current device (RCD) with a trip
range of 30 mA.
WARNING
THIS APPLIANCE MUST BE
EARTHED
Disconnecting devices
It must be possible to disconnect the
hob from the mains at all poles using
disconnecting devices. A contact dis-
tance of at least 3 mm must be ob-
served in the switched-off state. The
disconnecting devices are overcurrent
protection devices and residual current
protection devices.