Electrical connection
137
Danger of injury! All electrical work
must be undertaken by a suitably
qualified and competent person in strict
accordance with current national and
local safety and building code
regulations. Installation, repairs and
other work by unqualified persons
could be dangerous. Miele cannot be
held liable for unauthorised work.
Ensure power is not supplied to the
appliance until after installation or repair
work has been carried out. The
appliance is supplied with a mains
connection cable for connection to AC
50 Hz, 230 V.
The fuse rating must be at least 16 A.
Connection should be made via a
suitable isolator which complies with
national and local safety regulations.
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
current of 30 mA.
Connection to a switched socket is
recommended as this provides easier
access in the case of a service call.
If the switch is not accessible after
installation, an additional means of
disconnection must be provided for all
poles. The means of disconnection
must be incorporated in the fixed wiring
in accordance with the wiring rules.
When switched off there must be an all-
pole contact gap of 3 mm in the isolator
switch (including switch, fuses and
relays).
AC 230V, 50 Hz
The voltage and rated load are given on
the data plate situated at the front of
the oven frame visible with the oven
door open. Please ensure the
connection data matches the
household supply.
If the connection cable is damaged, it
must be replaced by a suitably qualified
electrician with a specialist connection
cable of type H 05 VV-F, available from
Miele, to avoid a hazard.
WARNING
THIS APPLIANCE MUST BE
EARTHED