Danger of injury!
All electrical work should be
undertaken by a suitably qualified
and competent person.
Installation, repairs and other work
by unqualified persons could be
dangerous. Miele cannot be held
liable for unauthorised work. Ensure
power is not supplied to the
appliance until after installation or
repair work has been carried out.
Ovens are supplied for connection with
an approx. 1.7 m long 3-core cable for
connection to a 230 V, 50 Hz supply.
The wires in the mains lead are
coloured as follows:
Green/yellow = earth;
Blue = neutral;
Brown = live
WARNING - THIS APPLIANCE MUST
BE EARTHED
Fuse rating is 16 A.
Connection should be made via a fused
connection unit or suitable isolator
which complies with national and local
safety regulations. For extra safety it is
advisable to protect the appliance with
a suitable residual current device
(RCD).
Connection to a switched socket is
recommended as this provides easier
access in the case of a service call.
If the switch is not accessible after
installation, an additional means of
disconnection must be provided for all
poles.
When switched off there must be an all-
pole contact gap of 3 mm in the isolator
switch (including switch, fuses and
relays according to EN 60335).
The voltage, rated load and fuse rating
are given on the
data plate
situated at
the front of the oven interior. Please
ensure that these match the household
mains supply.
If the connection cable is damaged, it
must be replaced by a Miele approved
service technician.
Electrical connection
128