See Installation Instruction Booklet be-
fore making electrical connection.
All electrical work should be under-
taken by a suitably qualified and
competent person in strict accor-
dance with national and local safety
regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can-
not be held responsible for un-
authorised work.
Ensure power is not supplied to the
appliance while installation or repair
work is being carried out.
The appliance must only be oper-
ated when built-in. This is to ensure
that all electrical parts are shielded.
Live parts must not be exposed.
The
voltage, rated load and fusing
are
given on the data plate, located inside
the side compartment. Ensure that
these match the household mains sup-
ply. Please quote these data, and the
model and serial number when contact-
ing the Miele Service dept.
Connection of this appliance should be
made via a suitable isolator which com-
plies with national and local safety reg-
ulations, and the on/off switch should
be easily accessible after the appliance
has been built in.
If the socket is not accessible after in-
stallation (depending on country) an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a residual current device with a trip cur-
rent of 30 mA (in accordance with DIN
VDE 0664, VDE 0100 Section 739).
When switched off there must be an
all-pole contact gap of 3 mm in the iso-
lator switch (including switch, fuses and
relays acc. to EN 60 335).
Electrical connection UK, ZA
61