Setting the water softener
To avoid the build-up of calcium de-
posits on crockery and in the dish-
washer the water needs to be softened,
if it is harder than 107 ppm.
To ensure a steady supply of soft water
the water softener unit must be:
– correctly set, and
– the salt reservoir in the floor of the
wash cabinet must be topped up
with
dishwasher reactivating salt
as soon as the
k
light comes on.
The water softener must always be set
to correspond with the water hardness
the first time the machine is used.
Your local water authority will advise
you on the water hardness in your area.
Setting the water softener
The hardness range is divided into 18
time settings and a zero position. The
dishwasher is set at the factory for a
water hardness setting "8", correspond-
ing to 339 ppm.
If your water supply is harder or softer
than this, then:
Use the touchpads on the control
panel to change the setting, (see
table).
Timed
set-
ting
°d
mg/l
° f
°e
ppm
CaCO3
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
6
7
8
9
10
11
12
13
15
17
19
22
24
28
32
38
48
71
107
125
142
160
178
196
214
231
267
303
338
392
427
498
570
676
854
1264
10,7
12,5
14,3
16,0
17,9
19,6
21,4
23,2
26,8
30,4
33,9
39,3
42,8
50,0
57,1
67,8
85,7
126,7
7,5
8,8
10,0
11,3
12,5
13,8
15,0
16,3
18,8
21,3
23,8
27,5
30,0
35,0
40,0
47,6
60,1
88,9
107
125
143
160
179
196
214
232
268
304
339
393
428
500
571
678
857
1267
Press
q
and
c
touchpads simulta-
neously, and whilst depressed,
switch the machine on using the
main switch "I-0".
"PO.."will appear in the display field.
Press
k
touchpad. The "P" will dis-
appear and setting "0" will appear
in the display field. The setting "0"
can now be changed if necessary.
To do this:
Press
c
touchpad as many times
as is necessary for the desired value
to appear in the display field.
Press
h
touchpad. "SP" appears.
Press
h
touchpad once more. The
setting will now be stored. The dis-
play field clears.
The machine is now ready for oper-
ation.