Programming special functions
The following extra options can be
used in conjunction with programmes
where appropriate.
1. Setting water flow to "level plus
time control" instead of "timed flow
(60 secs.)".
If the inlet water pressure (flow rate at
the stopcock) is less than 2.5 bar, insuf-
ficient water will flow into the wash
cabinet. By selecting "level plus time
control flow", more water will flow into
the wash cabinet, if there is an inlet
water pressure between 1 and 2.5 bar.
The setting is adjusted separately for
cold and hot water
Proceed as follows:
Switch off the dishwasher.
Press
q
and
c
at the same time,
hold them in and also switch on the
dishwasher with "I-0". "P..." appears
in the display field.
Press
G
selector. A "10" or "11" will
appear in the display field.
"10" =
Cold
water connection time
control (60 secs).
"11" =
Cold
water connection level
plus time control.
Press
c
touchpad to change from
"10" to "11" or vice versa.
Press
h
. touchpad "SP" appears in
the display.
Press
h
touchpad again. The
change has been recorded and the
display field clears.
Switch off the dishwasher.
Press
q
and
c
at the same time,
hold them in and also switch on the
dishwasher with "I-0".
"P..." appears in the display.
Press
o
selector. A "20" or "21" ap-
pears in the display.
"20" =
Hot
water connection time
control (60 secs).
"21" =
Hot
water connection level
plus time control.
Press
c
touchpad, to change from
"20" to "21" or vice versa.
Press
h
touchpad. "SP" appears in
the display.
Press
h
touchpad again. The
change has been recorded and the
display field clears.
2. Selecting a second interim rinse
A second interim rinse can be pro-
grammed for all programmes, to im-
prove the interim rinse result.
Switch off the dishwasher.
Press
q
and
c
at the same time,
hold them in and also switch on the
dishwasher with "I-0".
"P..." appears in the display.
Press
s
touchpad. A "30" or "31"ap-
pears in the display.
"30" = one interim rinse,
"31" = two interim rinses.