... steam suddenly escapes from the
appliance door.
Check whether
– the safety valve has tripped. Proceed
as described in "Pressure
release/Safety valve".
– the pressure release has tripped.
Proceed as described in "Pressure
release/Safety valve".
– the rubber door seal is not fitting
correctly or is damaged, e.g. cracks
are visible. Fit the seal correctly or, if
necessary, replace it.
... after switching on, the descaling
programme symbol
k
and
00
appear
in the programme/temperature
display, the
k
symbol also appears
on the left of the display, and the
appliance beeps.
– The appliance needs to be
descaled. Proceed as described in
"Cleaning and care - Descaling".
...
k
and
E04
appear in the
programme/temperature display and
0:06
appears in the time display.
The descaling process was interrupted
by a power cut or by being
inadvertently switched off.
The appliance will automatically carry
out a rinsing programme after being
switched on again to flush out any
descaling fluid. This process cannot be
aborted. Wait until you hear several
beeps, and the
g
symbol is flashing in
the time display. Now you can either
re-start the descaling process, or select
another programme.
... the following fault messages
appear in the
programme/temperature display.
For all fault messages:
The door can only be opened when:
-
the fault message is flashing
alternately with the set temperature,
-
the
g
symbol is flashing in the
time display,
-
the alarm has stopped.
If the display is not flashing, the
appliance is still processing the
fault.
F06
The temperature thermostat is
faulty.
– Switch the appliance off and call the
Service Department.
Problem solving guide
52
Summary of Contents for DG 4064
Page 61: ...61 ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...Alteration rights reserved 2810 M Nr 06 786 680 09 ...