F12
p
Water is not getting into the
appliance.
Check whether
– the stopcock is open. If necessary
open it and start the programme
again.
– the water inlet hose is faulty.
– the filter in the water inlet is blocked.
If you cannot remedy the fault yourself,
switch the appliance off and call a
plumber or the Service Department.
F13
The temperature in the cooking
compartment is too high.
The appliance has not cooled down
sufficiently during the cooling down
phase.
Check whether
– the stopcock is open. If necessary
open it and start the programme
again.
– the water nozzle on the rear wall of
the cooking compartment needs
descaling. Proceed as described in
"Water nozzle" in "Cleaning and
care".
If neither of the above is the problem, it
could be that the quantity of food being
cooked was too high. Very large
quantities of food, e.g. potatoes, will
affect the cooling down of the
appliance.
F14
p
Too little water is running into
the steam generator.
Switch the appliance off and then back
on again. If the fault message appears
again, switch the appliance off and call
the Service department.
F20
The overheating protection
mechanism has been activated.
Proceed as described in "Overheating
protection".
F27 The power supply was
interrupted while a programme was
running.
Check the cooking status and if
necessary, set a new cooking duration
and then press the Start/Stop button to
start the programme again.
F40
The electronics are carrying out a
self test.
F83
The temperature regulator is faulty
and the temperature in the cooking
compartment has risen above 125 °C.
The programme will be interrupted and
the cooling down phase will begin.
Switch the appliance off after the
cooling down phase and call the Ser-
vice Department.
Problem solving guide