Connection to the gas supply, or
conversion from one type of gas to
another, should only be undertaken
by an approved and registered gas
installer in strict accordance with
current local and national safety and
building regulations.
When converting to a different type of
gas, the main burner jets and the small
burner jets have to be changed.
Nominal rating at high setting
Gas type
MJ/h
NG
ULPG
15
15
Nominal ratings for ULPG are based on
propane gas.
Nominal rating at low setting
Gas type
MJ/h
NG
ULPG
5.99
5.89
Nominal ratings for ULPG are based on
propane gas.
Screw in the new jets according to the
following table.
Jet table
Main jet
C
Small jet
C
NG
1.8 / 34
1.10 / 0.42
ULPG
1.05 / 7
0.68 / 0.25
The jet markings refer to 1/100 mm of
the jet diameter.
Conversion to another type of gas