NORMAL MODE, AUTOMATIC "PRESSURE" OPERATION

The TASC can be setup to control to a desired pressure.  As boom sections of a balanced
sprayer are turned on and off, the control valve will open and close  to maintain a flow rate that
will give a constant pressure.  The control valve will adjust according to boom width only.
SPEED will not adjust flow rate.  To enter this mode do the following:

MODE SELECTOR switch to carrier application rate.  SETUP/OPERATE switch to
SETUP.  Use INC/DEC switch to set rate to 0.0.  Put  SETUP/OPERATE switch back to
OPERATE. Console will read  "

Flow  

Contl

 

OFF Auto ".

Monitoring a pressure gauge, use the INC/DEC switch to set the desired pressure.  You are
now set to operate at a predetermined pressure.  Injection pumps will track boom 

width changes

and speed changes

 to keep chemical rate per acre constant.  The console will display flow as

GAL/ACRE

 at speeds 

above

 1 mph.  

Below

 1 mph the console will display flow as 

GAL/MIN

.

NORMAL MODE, SPECIAL PURPOSE BOOM WIDTHS

For broadcast spraying operations on slopes, separate widths can be programmed into the 'B'
or 'C' widths on the TASC console.  Select the "Normal" mode and 'B' Width or 'C' Width on the
Boom Switch Panel.  Select the Width display function and the "SET-UP" mode on the TASC
console.  Enter the desired width in inches.

Now, whenever boom width 'B' or 'C' is selected on the switch panel, the TASC console will
automatically adjust its flow rate for the programmed width, regardless of the position of the
individual boom valves

Summary of Contents for Mid-Tech TASC 6000

Page 1: ...DSIDE SPRAYER OPERATIONS TASC MANUAL SUPPLEMENT MIDWEST TECHNOLOGIES INC 2733 E ASH STREET SPRINGFIELD IL USA TEL 217 753 8424 FAX 217 753 8426 999 1512 SOFTWARE VERSION 3 10 Date Code 98084 MID TECH...

Page 2: ...n mode set up functions Handgun mode operate functions Handgun mode special considerations Handgun mode typical operation Handgun mode manual valve override Handgun mode error messages Handgun mode pr...

Page 3: ...F OPERATION TASC roadside operations require at least TASC software level 3 10 or above Slave software level 3 0 or above the inclusion of an external handgun function switch an interface cable and a...

Page 4: ...mp section 4 7 4 in the TASC Manual TEST SPEED Using the INC DEC switch set a test flow rate in gallons per minute this rate is required before pumps can be accurately calibrated SCAN An Err message w...

Page 5: ...w control valve D The initial response of the flow control valve to the selection of the handgun mode is to open fully Once application has started the response of the flow control valve to the flow s...

Page 6: ...ng to the spray boom The TASC console will then be ready for the previously programmed broadcast spraying operations HANDGUN MODE MANUAL VALVE OVERRIDE The flow control valve can be set to a manual ov...

Page 7: ...tion occurs Once the problem is corrected Error 3 Pump is cleared by first selecting Normal and then returning to the Handgun mode on the switch panel Error 4 Error 4 Pump An Error 4 condition indicat...

Page 8: ...IR FIELD REF DATE TIME OPER HANDGUN MODE PRINTER OUTPUT SAMPLES The following two sample printouts show the typical printouts in the HANDGUN MODE The one on the left shows metric units and the one on...

Page 9: ...he INC DEC switch to set the desired pressure You are now set to operate at a predetermined pressure Injection pumps will track boom width changes and speed changes to keep chemical rate per acre cons...

Reviews: