HANDGUN MODE, ERROR MESSAGES

, see also section 8.0 in the TASC Manual:

Error-1:  "Error - 1, Pump #"  This indicates the displayed pump is running at its maximum rate.
An Error-1 condition lasting more than 5 seconds will cause all the injection pumps to stop
and the flow control valve to close, stopping all spraying operations.  Check power connec-
tions and programming.  Check that the pump is large enough for the desired flow.  Once the
problem is corrected, Error-1, Pump #  is cleared by first selecting Normal and then returning
to the Handgun mode on the switch panel.

Error-3:  "Error - 3, Pump #"  This indicates there are no sensor pulses being received from the
displayed pump.  An Error-3 condition lasting more than 5 seconds will cause all the injection
pumps to stop and the flow control valve to close, stopping all spraying operations.  Check
power, ground and fuses on the pump power cable.  Check the programming.  Check if the
pumps runs before the error condition occurs.  Once the problem is corrected, Error-3, Pump
# is cleared by first selecting Normal and then returning to the Handgun mode on the switch
panel.

Error-4:  "Error - 4, Pump #"  An Error-4 condition indicates that the displayed injection pump
is running when it should be off.  An Error-4 condition will immediately cause all the injection
pumps to stop and the flow control valve to close, stopping all spraying operations.  Check for
normal operation of the injection pump, the pump driver module may need to be replaced.
Once the problem is corrected, Error-4, Pump # is cleared by first selecting Normal and then
returning to the Handgun mode on the switch panel.

Error-5:  "Error -5. Pump F"  This indicates the carrier flow rate is exceeding the target rate and
the flow control valve is not responding to the consoles commands.  An Error-5 condition
lasting more than 5 seconds will cause all the injection pumps to stop and the flow control
valve to close, stopping all spraying operations.  Check the fuse and power and ground to the
flow control valve.  Check for a stuck valve.  Once the problem is corrected, Error-5  is cleared
by first selecting Normal and then returning to the Handgun mode on the switch panel.

Summary of Contents for Mid-Tech TASC 6000

Page 1: ...DSIDE SPRAYER OPERATIONS TASC MANUAL SUPPLEMENT MIDWEST TECHNOLOGIES INC 2733 E ASH STREET SPRINGFIELD IL USA TEL 217 753 8424 FAX 217 753 8426 999 1512 SOFTWARE VERSION 3 10 Date Code 98084 MID TECH...

Page 2: ...n mode set up functions Handgun mode operate functions Handgun mode special considerations Handgun mode typical operation Handgun mode manual valve override Handgun mode error messages Handgun mode pr...

Page 3: ...F OPERATION TASC roadside operations require at least TASC software level 3 10 or above Slave software level 3 0 or above the inclusion of an external handgun function switch an interface cable and a...

Page 4: ...mp section 4 7 4 in the TASC Manual TEST SPEED Using the INC DEC switch set a test flow rate in gallons per minute this rate is required before pumps can be accurately calibrated SCAN An Err message w...

Page 5: ...w control valve D The initial response of the flow control valve to the selection of the handgun mode is to open fully Once application has started the response of the flow control valve to the flow s...

Page 6: ...ng to the spray boom The TASC console will then be ready for the previously programmed broadcast spraying operations HANDGUN MODE MANUAL VALVE OVERRIDE The flow control valve can be set to a manual ov...

Page 7: ...tion occurs Once the problem is corrected Error 3 Pump is cleared by first selecting Normal and then returning to the Handgun mode on the switch panel Error 4 Error 4 Pump An Error 4 condition indicat...

Page 8: ...IR FIELD REF DATE TIME OPER HANDGUN MODE PRINTER OUTPUT SAMPLES The following two sample printouts show the typical printouts in the HANDGUN MODE The one on the left shows metric units and the one on...

Page 9: ...he INC DEC switch to set the desired pressure You are now set to operate at a predetermined pressure Injection pumps will track boom width changes and speed changes to keep chemical rate per acre cons...

Reviews: