The accuracy specification is defined as ± (n% r [count * resolution]) at 77 °F.
Vdc
Range
Resolution
Accuracy
Overload Protection
0–60 V
0.01 V
0.05% + 2
120 Vrms
Accuracies are specified from 2% to 100% of range.
Vac
Range
Resolution
Accuracy
Overload Protection
0–24 Vac rms
0.01 Vac
0.1% + 3
120 Vrms
Accuracies are specified from 2% to 100% of range.
Adc
Range
Resolution
Accuracy
Overload Protection
0–70 A
0.01 A
± 3% of reading ± 1A
1000 Arms
0–700 A
0.1 A
± 3% of reading ± 1A
1000 Arms
Accuracies are specified from 2% to 100% of range.
Aac
Range
Resolution
Accuracy
Overload Protection
0–70 A
0.01 A
± 3% of reading ± 1A
1000 Arms
0–700 A
0.1A
± 3% of reading ± 1A
1000 Arms
Accuracies are specified from 2% to 100% of range.
Ohm
Range
Resolution
Accuracy
Overload Protection
10Ω–2 M
Ω
1
Ω
2.0% + 4
120 Vrms
Continuity
Range
Resolution
Accuracy
Overload Protection
< 10
Ω
1
Ω
2.0% + 4
120 Vrms
Diode
Range
Resolution
Accuracy
Overload Protection
0–1.5 V
0.01 V
0.05% + 2
120 Vrms
Temperature
Range
Resolution
Accuracy
Overload Protection
-20–200 °F
-28–93 °C
1 °F
1 °C
1.0% + 5
--------