background image

 

GENERAL INFORMATION 

 

VS-1200: 

 
The VS-1200 is a Digital Signal Processor (DSP) based Frequency Domain voice scrambler offering a high level 
of voice privacy. The DSP converts the analog signal into quantitized digital data. It then converts the “Time 
Domain” signal into the “Frequency Domain”. This results in an audio “frequency spectrum”, which is then 
partitioned into bins that are encrypted by the non-linear key generator. The digitized data is converted back to 
the analog realm using a digital to analog converter. 
 
The above technique and the lack of synchronization result in excellent audio quality, high security and enable the 
VS-1XXX to be used in virtually any type of radio system. These systems include HF SSB, Conventional Two-
Way, Trunking, Voting and Simulcast. 
 
In addition to the scrambling functions the VS-1200 offers ANI and Emergency ANI encode in the following 
formats: 

 Motorola’s 

MDC-1200 

 Kenwood’s 

FleetSync 

 

M/A-Com’s G-Star (aka GE-Star) 

 DTMF 

 

5-Tone (all formats) 

 

VS-1000:

  

 
Midian’s VS-1000 voice inversion scrambler provides an entry level of voice security for two-way radio 
communications. The VS-1000 provides up to 16 different inversion frequencies that are selectable using 4-line 
binary. These inversion frequencies are programmable using Midian’s KL-3. The VS-1000 is compatible with 
Midian’s VPU series voice inversion scramblers. 
 

VS-1050:

  

 
Midian’s VS-1050 is a voice inversion scrambler with multi-format ANI encode. The VS-1050 has the same 
scrambling features as the VS-1000, but adds ANI and Emergency ANI encode in the following formats: 

 Motorola’s 

MDC-1200 

 Kenwood’s 

FleetSync 

 

M/A-Com’s G-Star (aka GE-Star) 

 DTMF 

 

5-Tone (all formats) 

 

 

3

Summary of Contents for VS-1000

Page 1: ...ambler with Multi Format ANI VS 1000 Voice Inversion Scrambler VS 1050 Voice Inversion Scrambler with Multi Format ANI Manual Revision 2009 06 26 Covers Firmware Revisions VS1xxx 01 31 00 Higher Cover...

Page 2: ...ng clear mode the consumption will decrease This is based on FFT scrambling When using voice inversion this will vary The VS 1000 and VS 1050 support 4 75 to 15 5 VDC The VS 1200 supports 4 75 to 10 V...

Page 3: ...l Two Way Trunking Voting and Simulcast In addition to the scrambling functions the VS 1200 offers ANI and Emergency ANI encode in the following formats Motorola s MDC 1200 Kenwood s FleetSync M A Com...

Page 4: ...e Hardware Installation Section of this manual 4 Program the scrambler per the Product Programming Section of this manual Note Midian is not responsible for any damage loss resulting from the use of M...

Page 5: ...he microphone P1 6 Orange Emergency Input Future Use P1 7 Yellow RX Audio In The VS 1XXX must be installed in the receive audio path after the CTCSS high pass filter and where any tone signaling is pi...

Page 6: ...ine would be connected to Binary Select 2 In 2 line binary mode this is the most significant bit MSB P2 6 Code Select 2 This line would be connected to Binary Select 4 In 3 line binary mode this is th...

Page 7: ...0 Hz tone into the speaker Adjust the output of the sine wave generator so that the transmitter produces 60 of rated modulation while PTT is pressed Note that if the audio source such as a speaker is...

Page 8: ...g this measurement so the power input leads of the scrambler must be connected to a switched power source within the radio Also the component that will need to be removed to break the TX audio path mu...

Page 9: ...VS 1xxx All three clip leads must be connected for reading and writing Turn power on to the VS 1xxx and within 15 seconds select Program Unit or Read Unit in the KL 3 software Upon power up the scram...

Page 10: ...sing a latched switch 1 Line Binary If using the binary mode and up to 2 codes are programmed this provides selection of 2 codes depending on the state of the code select line 2 Line Binary If using t...

Page 11: ...of 3 actions can bring the unit out of power save These are PTT COR or PTT VOX PTT When the PTT input of the VS 1XXX is activated the unit will come out of power save mode COR When the COR Input sees...

Page 12: ...2 MIDIAN CONTACT INFORMATION Midian Electronics Inc 2302 East 22nd Street Tucson Arizona 85713 USA Orders 1 800 MIDIANS Phone 520 884 7981 Fax 520 884 0422 E mail sales midians com Web www midians com...

Page 13: ...10K R9 10K 1 R11 10K 1 R12 75K R19 1 2M R20 36K R21 R17 R23 R22 1K R26 1K R25 4 7K R30 47K R31 100K R15 8 2K R16 56K R18 100K R14 27K R13 3 3K R28 560p C2 1u C3 1u C42 1u C12 100p C14 560p C11 0068u C...

Page 14: ...This page intentionally left blank...

Page 15: ......

Page 16: ......

Page 17: ...K R10 10K R9 10K 1 R11 10K 1 R12 75K R19 1 2M R20 36K R21 R17 R23 R22 1K R26 1K R25 4 7K R30 47K R31 100K R15 8 2K R16 56K R18 100K R14 27K R13 3 3K R28 560p C2 1u C3 1u C42 1u C12 100p C14 560p C11 0...

Page 18: ...This page intentionally left blank...

Page 19: ......

Page 20: ......

Reviews: