14
7.5.2.1 If TA
﹥
TS+1
℃
, the two fans operate. After 15 seconds, the compressor operates.
7.5.2.2 If TA≤TS after the compressor operates, this compressor will stop, and two fans last for working
all the time.
7.5.3 Auto fan acts as below rules:
7.5.5. The TIMER function is valid in the cooling mode.
7.6 Drying mode
7.6.1. When the unit starts to operate at drying mode, the compressor will start while the room
temperature is over 13
℃
. After the compressor started, the compressor will operate as below.
TA
℃
15
13
Compressor on
Operation conditon
Compressor off
7.6.1.1 When TA<13
℃
, the compressor stops. And the fan operates at low speed at all time.
7.6.1.2 When TA≥14
℃
, the compressor operates.
7.6.2. The fan operates with compressor.
14