8
If error repeats, call for service.
EC- Refrigerant leakage detection malfunction- Unplug the unit and plug it back in. If error repeats,
call for service.
Protection codes:
P1- Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats,
call for service
⑤
Power management feature(for power management models)
When the ambient temperature is lower (Cooling mode) or higher (Heating mode) than the setting
temperature for a period of time, the unit will be automatically operate power management feature.
The compressor and fan motor stop and the power management indicator light illuminates. When the
ambient temperature is higher (Cooling mode) or lower (Heating mode) than the setting temperature,
the unit will be automatically quit the power management feature. The power management indicator
light turns dark and the compressor and (or) fan motor run.
NOTE: When more than one codes occur, the priority of the code display order is:
E0—EC—E4—E2—E1—P1
Summary of Contents for PH Series
Page 1: ...MIDEA 50Hz PORTABLE PH SERIES ...
Page 11: ...9 4 Dimension Capacity Btu h W mm H mm D mm small body 329 318 615 big body 345 355 703 H W D ...
Page 13: ...11 6 Wiring Diagram MPPHA 05CRN7 QB6 MPPH 07CRN7 QB6G1 MPPH 08CRN7 QB6 MPPH 09CRN7 QB6 ...
Page 14: ...12 MPPHA 07CRN7 QB6 MPPHB 08CRN7 QB6 N MPPHB 09CRN7 QB6 N ...
Page 20: ...18 2 Use bolts to fasten the window sliders once they are adjusted to the Proper length ...