4. Specification
MSG-07CRN2
MSG-07HRN2
MSG-09CRN2
Ph-V-Hz
1, 220-240V~,50Hz
1, 220-240V~,50Hz
1, 220-240V~,50Hz
Capacity
Btu/h
7000
7000
9000
Input
W
780
780
1000
Rated current
A
3.5
3.5
4.4
EER
Btu/w.h
9.0,2.6
9.0,2.6
9.0,2.6
Capacity
Btu/h
-----
8000
-----
Input
W
-----
800
-----
Rated current
A
-----
3.6
-----
COP
W/W
-----
2.9
-----
A
4.4
4.4
6
A
18
18
19.8
Model
PG135X1C-4DZ2
PG135X1C-4DZ2
PG180X1C-4DZ3
Type
Rotary
Rotary
Rotary
Brand
TOSHIBA
TOSHIBA
TOSHIBA
Capacity
Btu/h
8086/8172
8086/8172
10800
Input
W
765/785
765/785
1015
Rated current(RLA)
A
3.52/3.34
3.52/3.34
4.5
Locked rotor Amp(LRA)
A
21
21.0
19.8
Thermal protector
UP3SE0591-T71
UP3SE0591-T71
UP3SE0591-T61
Capacitor
uF
25
25
30
Refrigerant oil
ml
400
400
400
Model
RPG13H
RPG13H
RPG13H
Brand Welling
Welling
Welling
Input
W
37.5
36.5
39.5
Capacitor
uF
1.2
1.2
1.2
Speed(hi/mi/lo) r/min
1020/960/900
1020/960/900
1100/1020/950
m3/h
430/400/370
430/400/370
470/440/410
dB(A)
35/32/30
35/32/30
36/32/30
Model
YDK24-6T
YDK24-6T
YDK24-6T
Brand Welling
Welling
WELLING
Input
W
70
70
70
Capacitor
uF
3
3
3
Speed
r/min
850
850
850
m
3
/h
1500
1500
1600
dB(A)
49
49
52
g
650
740
620
MPa
2.8
2.8
2.8
Liquid side/ Gas side
mm
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Max. refrigerant pipe length
m
10
10
10
Max. difference in level
m
5
5
5
℃
17-30
17-30
17-30
℃
18-45
-7 - 45
18-45
m
2
10-14
10-14
10-14
Model
Power supply
Cooling
Heating
Max. current
Starting current
Compressor
Indoor
fan motor
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R407C
Design pressure
Refrigerant
piping
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat
different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.