Service manual
- 26 -
9. Capacity table
9.1 MSG-07CRN2
SUMMER
Cooling mode
Indoor
Conditions
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
21ºC D
Total capacity kW
1.97
1.85
1.71
1.58
1.47
1.37
15ºC W
Sensitive capacity kW
1.44
1.38
1.29
1.20
1.13
1.05
Input kW.
0.67
0.70
0.73
0.79
0.88
0.91
24ºC D
Total capacity kW
2.13
2.04
1.90
1.80
1.68
1.55
17ºC W
Sensitive capacity kW
1.57
1.52
1.45
1.38
1.29
1.20
Input kW.
0.69
0.73
0.76
0.82
0.91
0.94
27ºC D
Total capacity kW
2.27
2.17
2.05
1.94
1.81
1.66
19ºC W
Sensitive capacity kW
1.73
1.67
1.60
1.52
1.42
1.32
Input kW.
0.71
0.75
0.78
0.84
0.94
0.97
32ºC D
Total capacity kW
2.53
2.43
2.35
2.18
2.00
1.88
23ºC W
Sensitive capacity kW
1.95
1.89
1.84
1.72
1.60
1.52
Input kW.
0.74
0.78
0.81
0.88
0.97
1.01
OUTDOOR TEMPERATURE DRY
9.2 MSG-07HRN2
SUMMER
Cooling mode
Indoor
Conditions
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
21ºC D
Total capacity kW
1.97
1.85
1.71
1.58
1.47
1.37
15ºC W
Sensitive capacity kW
1.44
1.38
1.29
1.20
1.13
1.05
Input kW.
0.67
0.70
0.73
0.79
0.88
0.91
24ºC D
Total capacity kW
2.13
2.04
1.90
1.80
1.68
1.55
17ºC W
Sensitive capacity kW
1.57
1.52
1.45
1.38
1.29
1.20
Input kW.
0.69
0.73
0.76
0.82
0.91
0.94
27ºC D
Total capacity kW
2.27
2.17
2.05
1.94
1.81
1.66
19ºC W
Sensitive capacity kW
1.73
1.67
1.60
1.52
1.42
1.32
Input kW.
0.71
0.75
0.78
0.84
0.94
0.97
32ºC D
Total capacity kW
2.53
2.43
2.35
2.18
2.00
1.88
23ºC W
Sensitive capacity kW
1.95
1.89
1.84
1.72
1.60
1.52
Input kW.
0.74
0.78
0.81
0.88
0.97
1.01
OUTDOOR TEMPERATURE DRY
WINTER
-7ºC D
-8ºC W
Capacity kW
2.76
2.42
2.22
1.95
1.68
1.47
Input kW.
0.86
0.78
0.73
0.67
0.59
0.53
Capacity kW
2.71
2.38
2.16
1.88
1.59
1.38
Input kW.
0.88
0.79
0.74
0.69
0.60
0.54
Capacity kW
2.69
2.34
2.14
1.83
1.51
1.25
Input kW.
0.91
0.80
0.76
0.70
0.62
0.57
Capacity kW
2.66
2.31
2.11
1.81
1.48
1.23
Input kW.
0.94
0.81
0.77
0.73
0.66
0.59
OUTDOOR CONDITIONS
Indoor
Conditions
12ºC D
11ºC W
7ºC D
6ºC W
4ºC D
3ºC W
0ºC D
-1ºC W
-4ºC D
-6ºC W
15ºC
18ºC
20ºC
22ºC
Summary of Contents for MSG-07CRN2
Page 2: ......
Page 15: ...Service manual 11 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Page 17: ...Service manual 13 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Page 21: ...Service manual 17 7 2 2 MSG 07HR MSG 09HR MSG 12HR...