Service manual
- 8 -
MSG-09HRN2
MSG-12CRN2
MSG-12HRN2
Ph-V-Hz
1, 220-240V~,50Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz
Capacity
Btu/h
9000
12000
12000
Input
W
1000
1330
1330
Rated current
A
4.4
6
6
EER
Btu/w.h
9.0,2.6
9.0 ,2.6
9.0 ,2.6
Capacity
Btu/h
11000
-----
14000
Input
W
1100
-----
1400
Rated current
A
4.9
-----
6.3
COP
W/W
2.9
-----
2.9
A
6
7
8
A
19.8
33
33
Model
PG180X1C-4DZ3
PG225X2C-4FT
PG225X2C-4FT
Type
Rotary
rotary
rotary
Brand
TOSHIBA
TOSHIBA
TOSHIBA
Capacity
Btu/h
10800
13550/13700
13550/13700
Input
W
1015
1290/1335
1290/1335
Rated current(RLA)
A
4.5
6.1
6.1
Locked rotor Amp(LRA)
A
19.8
33
33
Thermal protector
UP3SE0591-T61
UP3RE0591-T56
UP3RE0591-T56
Capacitor
uF
30
35
35
Refrigerant oil
ml
400
480
480
Model
RPG13H
RPG18H
RPG18H
Brand Welling
WELLING
WELLING
Input
W
38.5
50
50
Capacitor
uF
1.2
1.5
1.5
Speed(hi/mi/lo) r/min
1100/1020/950
1250/1150/1050
1250/1150/1050
m3/h
470/440/410
500/450/400
500/450/400
dB(A)
36/32/30
40/36/34
40/36/34
Model
YDK24-6T
YDK25-6C
YDK25-6C
Brand Welling
WELLING
WELLING
Input
W
70
68
68
Capacitor
uF
3
2.5
2.5
Speed
r/min
850
900
900
m
3
/h
1600
1900
1900
dB(A)
52
55
55
g
800
780
1100
MPa
2.8
2.8
2.8
Liquid side/ Gas side
mm
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
12.7
Ф
6.35/
Ф
12.7
Max. refrigerant pipe length
m
10
10
10
Max. difference in level
m
5
5
5
℃
17-30
17-30
17-30
℃
-7 - 45
18-45
18-45
m
2
14-21
18-26
18-26
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R407C
Design pressure
Refrigerant
piping
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Max. current
Starting current
Compressor
Indoor
fan motor
Model
Power supply
Cooling
Heating
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat
different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.