4
3
–
To remove the pump:
Remove the service panel.
Caution:
Under normal conditions,
approximately
1 quart of water will drain out when the pump
cleanout is removed.
Place a shallow pan under the drain cleanout.
Turn the pump cleanout counterclockwise
approximately 2 turns, then pull outward.
1.
2.
3.
Strainer
Note:
Remove any debris or foreign objects from the
strainer and interior of the pump before reinstalling.
Remove the drain hoses from the pump:
Note:
The drain hoses are dif
fi
cult to remove.
Squeeze each clamp and slide it back.
Carefully break each hose loose by inserting
a small
fl
at-blade screwdriver under the
hose to break the seal.
Remove the tub outlet hose from the pump
inlet.
Remove the drain hose from the pump
outlet.
4.
a.
b.
c.
d.
Disconnect the 2 wires from the pump.
5.
Remove the 2 Phillips-head screws that hold the
pump to the chassis.
Lift the pump to release from the base.
6.
7.
Remove the pump thru the enlarged opening on
the left side of the front frame.
8.