Service manual for Wash and Dry Combo product
Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
28
-
Door can’t be locked (E30)
Door can’t be locked (E30)
Is the door closed correctly?
Check the wire connection.
Is the terminal connected
correctly?
Is the wires open cycled?
Check the Door Lock
Step 1: Check the resistance between Pin 2 and Pin 3
with the Slipper Held right as figure below. It should be in
range from 30 to 100Ω. Otherwise, the lock is failure.
Step 2: Hold the Locker Slip Left as figure above. Give a
power pulse to the Lock between Pin 2 and Pin 3. Then
release the Slipper. It should take the place without any
movement. Otherwise, the lock is failure.
NOTE: The power pulse to the Lock should be less
than ONE second. Otherwise, it will be damaged.
Step 3: Give a power pulse to the Lock between Pin 2
and Pin 3 again. The slipper should move back to its
original place immediately. Otherwise, the lock is failure.
Now, the lock can be confirmed OK.
Replace the PCBs.