![background image](http://html1.mh-extra.com/html/midea/mfc120-du1321ds-c14e-us/mfc120-du1321ds-c14e-us_service-manual_1791295022.webp)
Service manual for Wash and Dry Combo product
Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
21
-
module
temperature
failure
operation
E50/E58
Inverter
module failure
Unit will stop
operation
E50/E5A
Connection
failure
between
Inverter
module and
Main Control
PCB
Unit will stop
operation
E50/E5B
Inverter
module failure
Unit will stop
operation
E50/E5C
Over voltage,
inverter
module
Unit will stop
operation
E50/E5D
Low voltage,
inverter
module
Unit will stop
operation
E50/E5E
Inverter
module failure
Unit will stop
operation
E64
Signal
between Main
PCB and
Inverter PCB
abnormal
Unit will stop
operation