background image

 Page  17

Clean the bucket

Clean the air filter 

When not using the unit for long time periods 

Clean the Grille and Case

Care and Maintenance

·  Use water and a mild detergent. Do not use bleach or abrasives.
·  Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause 
   the insulation to deteriorate, or cause the unit to rust. 
·  The air intake and outlet grilles get soiled easily, so use a vacuum attachment or brush to clean.

·  Remove the filter every two weeks based on normal operating conditions.
·  To remove the filter, pull filter outwards.
·  Wash the filter with clean water then dry.
·  Re-install the filter, replace Bucket.

Care and cleaning of the dehumidifier
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.

Every few weeks, clean the bucket to prevent growth of mold, mildew and bacteria. Partially fill the 
bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty and 
rinse. 
Note: Do not use a dishwasher to clean the bucket. After clean, the bucket must be in place and 
securely seated for the dehumidifier to operate.

 

·  After turning off the unit, wait one day before emptying the bucket. 
·  Clean the main unit, water bucket and air filter.
·  Wrap the cord with the power cord buckle.
·  Cover the unit with a plastic bag. 
·  Store the unit upright in a dry, well-ventilated place.

Care and

Maintenance

      

    

    

   otherwise water is become ice that will cause the 
   water hose blocked up and the unit failure. Make sure 
   to empty the bucket once a week when using the 
   pump draining feature. When the pump draining 
   feature is not being used, remove the pump drain 
   hose from the outlet.
·  Press the pump drain hose outlet in and take the 
   pump drain hose out from it (See Fig.13). Make sure 
   do not let the water in the pump hose drip to the 
   floor. 

2,Take the pump 

   drain hose out

 

1,Press the pump drain hose outlet in

 

            CAUTION  
DO NOT operate the dehumidifier without a 
filter because dirt and lint will clog it and 
reduce performance.

Summary of Contents for MAD50P1ZWS

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...tures 13 Removing the collected water 15 Other features 14 Clean the grille and case 17 Clean the bucket 17 Troubleshooting Tips 18 Clean the air filter 17 When not using the unit for long time period...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...n damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning Do not run cord under carpeting Do not cov...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...al performance of our products the design specifications of the unit are subject to change without prior notice Control panel Panel Water level window Water bucket Water bucket Handle both sides Handl...

Page 12: ...ure damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a basement will have li...

Page 13: ...ing the filter press the Filter button and the light will go off Press the filter button for 3 seconds when the unit is on or off to initiate the Wireless connection mode The LED DISPLAY shows AP to i...

Page 14: ...the bucket is full or when the bucket is removed or not replaced in the Wait 3 minutes before resuming operation After the unit has stopped it can not be restart operation in the first 3 minutes This...

Page 15: ...aining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting When the Auto Start Auto Stop times are set withi...

Page 16: ...ale threaded end When you remove the plastic cover if there is some water in the back drain outlet of the unit you must dry it Make sure the hose is secure so there are no leaks and the end of the hos...

Page 17: ...nd add a little mild detergent Swish it around in the bucket empty and rinse Note Do not use a dishwasher to clean the bucket After clean the bucket must be in place and securely seated for the dehumi...

Page 18: ...tion may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The dehumidifier has Auto defrost feature These are error codes and protection codes See t...

Page 19: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the serv...

Page 20: ...1 80g 2 A4 210 290 3 4 5 1 DP DL 2 3 DP DL 4...

Page 21: ...Pg6 Pg10 WARNING for Using R32 R290 Refrigerant...

Reviews: