Midea MAD50P1ZWS Owner'S Manual & Installation Manual Download Page 14

COMFORT button(on some models)

Press to starts/stops the comfort dehumidifying 
operation.  
Note:  On this operation,the unit can not be set 
humidity level.  For some models, under comfort 
dehumidifying operation, press Up/Down button will
cancel this feature.

 Page 14

Other features

 Operating

Instructions

·  Humidity Set Control  buttons

UP/DOWN buttons

·  TIMER Set Control buttons

Use the Up/Down buttons to set the Auto start and 
Auto stop time from 0.0 to 24.  

The humidity level can be set within a range of 35%
RH(Relative Humidity) to 85%RH(Relative Humidity) 
in 5% increments. For drier air , press the       (or       )
button and set to a lower percent value(%). For 
damper air, press the      (or        ) button and set  a 
higher percent value(%).    

POWER button

Press to turn the dehumidifier on and of

f.

PUMP button(on some models)

 

Press to activate the pump operation.
Note: Make sure the pump drain hose is installed into 
the unit and the continuous drain hose is removed 
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer 
to the next pages for removing the collected water. Do 
not use this operation when the outdoor temperature
is equel to or less than 0 C (32 F).

 

Bucket Full Light
Glows when the bucket is ready to be emptied.

Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to 
run until the frost disappears.

proper position. 
For some models, the fan motor will continue to run
for 30 seconds.

Auto Shut Off
The dehumidifier shuts off when the bucket is full, or
when the bucket is removed or not replaced in the

Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart 
operation in the first 3 minutes.This is to protect the 
unit. Operation will automatically start after 3 minutes.

O

O

ION button(on some models)

DRYER button(on some models)

Press to activate the ionizer. Anions are automatically
generated by ionization. The anions deactive the 

Press to activate the dryer operation. Press it again to
stop the function.

 

 

Display

Shows the set % humidity level from 35% to 85% or 
auto start/stop time (0~24) while setting, then shows 
the actual(±5% accuracy) room % humidity level in a 
range of 30% RH(Relative Humidity) to 90%RH(Relative 
Humidity).
Error Codes and Protection Code:
AS-Humidity sensor error--Unplug the unit and plug it 
       back in. If error repeats, call for service.
ES-Tube Temperature sensor of the evaporator error-- 
       Unplug the unit and plug it back in. If error repeats, 
       call for service. 
P2-Bucket is full or bucket is not in right position-- 
       Empty the bucket and replace it in the right 
       position.(only available for the unit with no pump 
       feature.)
P2-Bucket is full -- Empty the bucket.(only available for 
       the unit with pump feature.)
Eb-Bucket is removed or not in right position-- Replace 
       the bucket in the right position.(only available for 
       the unit with pump feature.)

Note: When one of the above malfunctions occurs, 
turn off the unit, and check for any obstructions. 
Restart the unit, if the malfunction is still present, turn 
off the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualified 
person for service.    

airborne chemical vapors and dust particles. Press it 
again to stop the function.   

Summary of Contents for MAD50P1ZWS

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...tures 13 Removing the collected water 15 Other features 14 Clean the grille and case 17 Clean the bucket 17 Troubleshooting Tips 18 Clean the air filter 17 When not using the unit for long time period...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...n damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning Do not run cord under carpeting Do not cov...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...al performance of our products the design specifications of the unit are subject to change without prior notice Control panel Panel Water level window Water bucket Water bucket Handle both sides Handl...

Page 12: ...ure damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a basement will have li...

Page 13: ...ing the filter press the Filter button and the light will go off Press the filter button for 3 seconds when the unit is on or off to initiate the Wireless connection mode The LED DISPLAY shows AP to i...

Page 14: ...the bucket is full or when the bucket is removed or not replaced in the Wait 3 minutes before resuming operation After the unit has stopped it can not be restart operation in the first 3 minutes This...

Page 15: ...aining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting When the Auto Start Auto Stop times are set withi...

Page 16: ...ale threaded end When you remove the plastic cover if there is some water in the back drain outlet of the unit you must dry it Make sure the hose is secure so there are no leaks and the end of the hos...

Page 17: ...nd add a little mild detergent Swish it around in the bucket empty and rinse Note Do not use a dishwasher to clean the bucket After clean the bucket must be in place and securely seated for the dehumi...

Page 18: ...tion may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The dehumidifier has Auto defrost feature These are error codes and protection codes See t...

Page 19: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the serv...

Page 20: ...1 80g 2 A4 210 290 3 4 5 1 DP DL 2 3 DP DL 4...

Page 21: ...Pg6 Pg10 WARNING for Using R32 R290 Refrigerant...

Reviews: