Midea MAD50P1ZWS Owner'S Manual & Installation Manual Download Page 5

Safety 

Precautions

 Page 5

   

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

1.

   

Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific 
information on the type, the amount and the CO

2

 equivalent in tonnes of the fluorinated 

greenhouse gas(on some models), please refer to the relevant label on the unit itself.

2.

 

Installation, service, maintenance and repair of this unit must be performed by a certified 
technician.

3.

 

Product uninstallation and recycling must be performed by a certified technician.

Sociable Remark

DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste 
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:

When using this dehumidifier in the European countries, the following information 
must be followed:

·   The municipality has established collection systems, where electronic waste can be disposed 
    of at least free of charge to the user.
·   When buying a new product, the retailer will take back the old product at least free of charge.
·   The manufacture will take back the old appliance for disposal at least free of charge to the user.
·   As old products contain valuable resources, they can be sold to scrap metal dealers. Wild 
    disposal of waste in forests and landscapes endangers your health when hazardous 
    substances leak into the ground-water and find their way into the food chain. 

Summary of Contents for MAD50P1ZWS

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...tures 13 Removing the collected water 15 Other features 14 Clean the grille and case 17 Clean the bucket 17 Troubleshooting Tips 18 Clean the air filter 17 When not using the unit for long time period...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...n damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning Do not run cord under carpeting Do not cov...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...al performance of our products the design specifications of the unit are subject to change without prior notice Control panel Panel Water level window Water bucket Water bucket Handle both sides Handl...

Page 12: ...ure damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a basement will have li...

Page 13: ...ing the filter press the Filter button and the light will go off Press the filter button for 3 seconds when the unit is on or off to initiate the Wireless connection mode The LED DISPLAY shows AP to i...

Page 14: ...the bucket is full or when the bucket is removed or not replaced in the Wait 3 minutes before resuming operation After the unit has stopped it can not be restart operation in the first 3 minutes This...

Page 15: ...aining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting When the Auto Start Auto Stop times are set withi...

Page 16: ...ale threaded end When you remove the plastic cover if there is some water in the back drain outlet of the unit you must dry it Make sure the hose is secure so there are no leaks and the end of the hos...

Page 17: ...nd add a little mild detergent Swish it around in the bucket empty and rinse Note Do not use a dishwasher to clean the bucket After clean the bucket must be in place and securely seated for the dehumi...

Page 18: ...tion may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The dehumidifier has Auto defrost feature These are error codes and protection codes See t...

Page 19: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the serv...

Page 20: ...1 80g 2 A4 210 290 3 4 5 1 DP DL 2 3 DP DL 4...

Page 21: ...Pg6 Pg10 WARNING for Using R32 R290 Refrigerant...

Reviews: