SECTION 2
INSTALLATION
30
3. Press
to leave the BELTS menu.
4. Press
again to leave the SYSTEM
CONFIGURATION menu.
SWITCHING PHOTO SENSOR
CAUTION
Disconnect power by employing proper OSHA
Lock-Out Tag-Out procedure before switching
Photo Eye.
1. Open the access door and disconnect the yellow
electrical connector fitting to the photo eye
assembly.
2. Remove the two screws securing the photo eye
assembly to the control box.
3. Remove the four nuts securing the photo eye to
the housing.
4. Rotate the photo eye 180 degrees and affix the
photo eye with the four nuts.
5. Replace the photo eye assembly in the opposite
control box by securing the photo eye assembly in
position.
6. Reconnect the yellow electrical connector fitting to
the photo eye assembly.
7. Replace the photo eye cover on the opposite
control box, where the photo eye assembly was
removed.
8. Apply power to the unit.
9. Adjust the photo eye height by loosening the two
screws securing the photo eye assembly and
sliding the photo eye assembly either up or down,
such that the beam is approximately 1/4 inch
above the belt.
NOTE:
This is MUCH easier in reduced light.