15
DIGITAL RACK MIXER M32R User Manual
(2)
LED Display
The LED display illustrates when the Dynamics are functioning for the selected
channel by illuminating the red
COMP
LED. The level of attenuation that is
being applied to the signal is shown as a value between 0 dB and -30 dB.
Please note that, when pressing the
VIEW
button, the attenuation level
displayed on the Main Display shows a value of between 0 dB and -60 dB.
(3)
COMP
Pressing the COMP button engages the compressor for the selected channel.
(4)
VIEW
Press the VIEW button to access more detailed parameters on the
Main
Display
. See the section Main Display - dyn for more details.
1.6 Equaliser
(1)
MODE Select Button and Display
Pressing the
MODE
button cycles through each of the EQ modes for the
currently selected frequency range. Each of the modes and the frequency
ranges to which they apply are listed below:
HCUT
A high-cut function which attenuates signals above the selected frequency.
HSHV
A high-shelving function which boosts or attenuates signals above the
selected frequency. Only available with the
HIGH 2 - HIGH
setting.
VEQ
A bell filter that provides a more ‘Vintage EQ’ sound. Available on all
frequency settings.
PEQ
A bell filter that provides a classic ‘Parametric EQ’ sound. Available on all
frequency settings.
LSHV
A low-shelving function which boosts or attenuates signals below the
selected frequency. Only available with the
LOW 2 - LOW
setting.
LCUT
A low-cut function which attenuates signals below the selected frequency.
NOTE:
Low-Cut and High-Cut Modes do not have Gain and Width settings.
(2)
WIDTH Rotary Control
The
WIDTH
rotary control determines the span of frequencies around that
specified by the
FREQUENCY
rotary control, which will be affected by
adjusting the
GAIN
control.
(3)
FREQUENCY Rotary Control
Select the specific frequency to be adjusted with the
FREQUENCY
rotary control. Each frequency can be adjusted between 20 Hz and 20 kHz.
The equaliser provides four discreet filter bands for input channels and even
six discreet bands for buses and matrices as follows:
7 - Individual Band Frequencies
HIGH
A band intended for high frequencies, with access to
HCUT
,
HSHV
,
VEQ
and
PEQ
EQ modes.
HI MID
A band intended for high-mid frequencies, with access to
VEQ
and
PEQ
EQ modes.
LO MID
A band intended for low-mid frequencies, with access to
VEQ
and
PEQ
EQ modes.
LOW
A band intended for low frequencies, with access to
LCUT
,
LSHV
,
VEQ
and
PEQ
EQ modes.
HIGH 2
Press
HIGH
and
HI MID
concurrently to access the
HIGH 2
band of
any bus equaliser.
LOW 2
Press
LOW
and
LO MID
concurrently to access the
LOW 2
band of any
bus equaliser.
(4)
GAIN Rotary Control
Boost or attenuate the selected frequency by turning the
GAIN
rotary
control. The selected equaliser band is inactive when the Gain control is in
the centre position (0 dB).
(5)
EQ Button
Engages the EQ function for the selected channel.
(6)
VIEW
Press the
VIEW
button to access more detailed parameters on the
Main Display
. See the section Main Display - eq for more details.
(1)
(2) (3) (4)
(5)
(6)
(7)