Installation and user manual
D R Y 8 0 0 / 1 2 0 0 M e t a l
V01/2022
|
1 9
4.6
Compressor regulation
The start of the compressor is delayed by 3 minutes due to it‘s protection. Depending on the
humidity and ambient temperature, this may take longer. If the compressor stops, it will start
automatically after 3 minutes at the earliest. The user must not manipulate the setting element of
this time protection. The task of time protection is to equalize the pressures of the refrigerant in the
dehumidifier‘s system.
5.
INSTALLATION MANUAL
After a long period of inactivity, it is normal for the compressor to try to start 4-6 times
before finally turning on. It also depends on the current air temperature. A lower ambient
temperature (approx. 22°C) requires more attempts, a higher temperature (approx. 30°C)
usually requires only 1 attempt.
The appliance must be installed in accordance with national installation and
wiring regulations!
Please note that the screws and dowels supplied with the appliance may only be
used on a solid concrete or a brick wall. Please check the base material and select
suitable screws and dowels.
The location of the device must be in accordance with the STN 33 2000-7-702
standard. It is recommended to place the device outside zones 0,1 and 2. When
placing the device in zones 2 or 1, the STN must be observed.
It is necessary to place the device outside zones where cleaning with spraying
water is expected. Connection to the electric network and protection must comply
with relevant standards. The power supply of the device must be realized by a
protective isolating transformer or protected by a residual current device with a
rated residual breaking current not exceeding 30 mA when installed in rooms
where water can be found.
Summary of Contents for DRY 1200 METAL
Page 25: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 2 5 ...
Page 47: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 4 7 ...
Page 48: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 4 8 ...
Page 52: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 5 2 ...
Page 53: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 5 3 ...
Page 61: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 6 1 ...
Page 62: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 6 2 Notes ...
Page 63: ...Installation and user manual D R Y 8 0 0 1 2 0 0 M e t a l V01 2022 6 3 Notes ...