RS Baud Rate / Default Timeout:
RS DIP Switches
RS Baud Rate
Default Timeout
DIP
(baud)
3
2
1
0
0
0
1200
28 ms
0
0
1
2400
14 ms
0
1
0
4800
7 ms
0
1
1
9600
4 ms
1*
0*
0*
19200
2 ms
1
0
1
38400
1 ms
1
1
0
57600
1 ms
1
1
1
115200
1 ms
* Setting required for communication with the MIGRA (do not adjust!)
Parity / Receive Timeout:
RS DIP Switches
Parity
Receive Timeout
DIP
6
5
4
0
0
0
none
default timeout
0*
0*
1*
even
default timeout
0
1
0
odd
default timeout
0
1
1
none
30 ms
1
0
0
none
3 x default timeout
1
0
1
even
3 x default timeout
1
1
0
odd
3 x default timeout
1
1
1
none
60 ms